CSX Compact Low Voltage Soft Starter

EMX3 Low Voltage Soft Starter
Compact size
The CSX is a compact and lightweight unit, so it is suitable for installation in small spaces and is the ideal replacement for older starters.
Easy-to-use adjustments
The CSX is easy to configure, with three simple adjustments. Select the initial start voltage, start ramp time and stop ramp time (if required), and the starter is ready to go. Rotary dials allow reliable, repeatable confguration with no need to navigate through a menu and no difficult-to-use dip switches.
Integrated bypass contactors
Integrated bypass contactors simplify installation by reducing the need to select and connect additional equipment. Because the contactors are already contained within the starter, the overall size of the installation is also smaller. Bypassing the starter while the motor is running reduces the amount of heating, so the starter can usually be installed with no additional ventilation.
Communications
CSXi soft starters integrate into your existing DeviceNet, Modbus, Profibus or Ethernet network using easy-to-install plug-in communication interfaces. The optional remote operator can be installed to provide remote feedback, including current, temperature and starter status.
Finger Guards
For enhanced personnel safety and protection, AuCom has developed insulating finger guards, which install quickly and easily onto 75 kW ~ 110 kW CSX Series units to provide IP20 protection.
Mains Supply |
||
Mains voltage (L1, L2, L3) | ||
CSX-xxx-V4 | 3 x 200 VAC ~ 440 VAC (+ 10% / - 15%) | |
CSX-xxx-V6 | 3 x 200 VAC ~ 575 VAC (+ 10% / - 15%) | |
Mains frequency (at start) | 45 Hz to 66 Hz | |
Rated insulation voltage | 600 VAC | |
Form designation | Bypassed semiconductor motor starter form 1 | |
Control Voltage (A1, A2, A3) | ||
CSX-xxx-xx-C1 | 110-240 VAC (+ 10% / - 15%) | |
or 380-440 VAC (+ 10% / - 15%) | ||
CSX-xxx-xx-C2 | 24 VAC/VDC (± 20%) | |
Current consumption (during run) | < 100 mA | |
Current consumption (at power-up) | ||
CSX-xxx-xx-C1 | 10 A | |
CSX-xxx-xx-C2 | 2 A | |
|
||
Start (terminal 01) | Normally Open | |
150 kΩ @ 300 VAC and 5.6 kΩ @ 24 VAC/VDC | ||
Stop (terminal 02) | Normally Closed | |
150 kΩ @ 300 VAC and 5.6 kΩ @ 24 VAC/VDC | ||
|
||
Main contactor (terminals 13, 14) | Normally Open | |
6 A, 30 VDC / 6 A, 250 VAC resistive | ||
Programmable relay (terminals 23, 24) | Normally Open | |
6 A, 30 VDC / 6 A, 250 VAC resistive | ||
|
||
Degree of protection CSX-007 to CSX-055 | IP20 | |
Degree of protection CSX-075 to CSX-110 | IP00 | |
Operating temperatures | - 10 °C to + 60 °C | |
Humidity | 5% to 95% Relative Humidity | |
Pollution degree | Pollution Degree 3 | |
Vibration | IEC 60068 Test Fc Sinusoidal | |
4 Hz to 13.2 Hz: ± 1 mm displacement | ||
13.2 Hz to 200 Hz: ± 0.7 g | ||
|
||
Equipment class (EMC) | Class B | |
Conducted radio frequency emission | 0.15 MHz to 0.5 MHz: < 56-46 dB (µV) | |
0.5 MHz to 5 MHz: < 46 dB (µV) | ||
5 MHz to 30 MHz: 50 dB (µV) | ||
Radiated radio frequency emission | 30 MHz to 230 MHz: < 30 dB (µV/m) | |
230 MHz to 1000 MHz: < 37 dB (µV/m) | ||
This product has been designed as Class A equipment. Use of this product in domestic environments may cause radio interference, in which case the user may be required to employ additional mitigation methods. | ||
|
||
Electrostatic discharge | 4 kV contact discharge, 8 kV air discharge | |
Radio frequency electromagnetic field | 0.15 MHz to 1000 MHz: 140 dB (µV) | |
Rated impulse withstand voltage (Fast transients 5/50 ns) | 2 kV line to earth, 1 kV line to line | |
Voltage dip and short time interruption | 100 ms (at 40% nominal voltage) | |
Harmonics and distortion | IEC61000-2-4 (Class 3), EN/IEC61800-3 | |
|
||
Rated short-circuit current CSX-007 to CSX-037 | 5 kA | |
Rated short-circuit current CSX-045 to CSX-110 | 10 kA | |
|
||
During Start | 3 watts / ampere | |
During Run | 10 watts typical | |
|
||
RCM | IEC 60947-4-2 | |
CE | EN 60947-4-2 | |
CCC | GB 14048.6 | |
EAC | TP TC 004/2011, TP TC 020/2011 | |
Marine | Lloyds Marine No 1 Specification | |
UL / C-UL | UL 508 |